Commercial Standards (Emissions & Immunity)

Radiated Emission

  • Standard: CISPR 11, EN55022, (FCC?)
  • Range: 30MHz to 3GHz

Radiated Immunity

  • Standard: IEC 61000-4-3 Pre compliance
  • Range: 80 MHz to 3GHz ; 1 V/m, 3 V/m & 10 V/m

Conducted Emission

  • Standard: CISPR 11 / EN 55011/22
  • Range: 150KHz to 30MHz
  • LISN: Upto 100Amps

Conducted Immunity (Commercial Standards IEC 61000-4-X)

  • IEC 61000-4-2 : ESD: Air discharge and Contact Discharge: Upto 30KV.
  • IEC 61000-4-4 : EFT: Fast transients to ± 5.5 kV, as per EN 61000-4-4. Single Phase AC CDN Max 16A & DC 10A. Capacitive Coupling Clamp for I/O Lines.
    Note: DC Source to be arranged by customer.
  • IEC 61000-4-5 : Surge: Surges up to ± 7kV (2 & 12 ohm) (differential & common mode), as per EN 61000-4-5. Single Phase AC CDN Max 16A & DC 10A. CDN DCD for 4 unshielded Unsymmetrical interconnection Lines current 1A.
    Note: DC Source to be arranged by customer.
  • IEC 61000- 4-6 : 1V/m, 3V/m & 10V/m (0.15MHz – 80MHz) Single Phase CDN Max 16A for two or three Supply lines. EM Clamp for I/O lines.
  • IEC 61000-4-11 & 4-29 : Voltage Dips, Interrupts & Variations : Single Phase AC and DC voltage dips up to 300 V AC & DC.
    Note: DC Sources to be arranged by customer.
  • IEC 61000-4-12 : Ring Wave : Upto +-7KV.

Automotive Standards (ISO, JASO, OEM)

1. ESD: ISO 10605

  • Upto 30Kv

2. ISO 16750 – 2

(Edition 5, 2023 -07)

  • Direct current supply voltage
  • Overvoltage
  • Superimposed alternating voltage
  • Slow decrease and increase of supply voltage
  • Discontinuities in supply voltage
  • Reset behaviour at voltage drop
  • Reversed voltage
  • Withstand against supply voltage transients
  • Open circuit test
  • Short circuit protection

3. ISO 7637-2

(Supply Line Transients)

  • Pulse 1
  • Pulse 2a
  • Pulse 2b
  • Pulse 3a
  • Pulse 3b
  • Pulse 4
  • Pulse 5a / 5b

4. ISO 7637-3

(Signal Line Transients)

  • Fast transient pulses
  • Capacitive coupling clamp method

5. JASO D 001

  • Supply voltage test
  • Overvoltage test
  • Undervoltage test
  • Voltage fluctuation test
  • Reverse polarity test

6. JASO D 014-2: 2-14-3

  • Fast transient pulses
  • Surge immunity test

7. JASO D 016 (EMC Tests)

  • Conducted emission
  • Conducted immunity

8. OEM (Manufacturer) : LV124 & LV 148

LV124

  • LV124-01a_LONG_TERM_OVERVOLTAGE
  • LV124-01b_LONG_TERM_OVERVOLTAGE
  • LV124_TRANSIENT_UNDERVOLTAGES
  • LV124-SLOW-DECREASE-AND-INCREASE-OF-THE-SUPPLY-VOLTAGE-FOR-OPERATION-WITHOUT-STORAGE-PART -1
  • LV124-SLOW-DECREASE-AND-INCREASE-OF-THE-SUPPLY-VOLTAGE-FOR-OPERATION-WITHOUT-STORAGE-PART - 2
  • LV124-SLOW DECREASE & ABRUPT INCREASE OF THE SUPPLY VOLTAGE
  • LV124_RESET_BEHAVIOUR
  • LV124_SHORT_INTERRUPTIONS
  • LV124_REVERSE_POLARITY
  • LV124_CONNECTOR_INTERRUPTION

LV148

  • LV148-E48-01a_LONG_TERM_OVERVOLTAGE
  • LV148-E48-01b_LONG_TERM_OVERVOLTAGE
  • LV148-E48-02_TRANSIENT_LOADS_OVERVOLTAGES
  • LV148-E48-03_TRANSIENT_UNDERVOLTAGES
  • LV148-E48-06A-SLOW-DECREASE-AND-INCREASE-OF-THE-SUPPLY-VOLTAGE-FOR-OPERATION-WITHOUT-STORAGE-PART -1
  • LV148-E48-06b-SLOW-DECREASE-AND-INCREASE-OF-THE-SUPPLY-VOLTAGE-FOR-OPERATION-WITHOUT-STORAGE-PART -1
  • LV148-E48-06c-SLOW-DECREASE-AND-INCREASE-OF-THE-SUPPLY-VOLTAGE-FOR-OPERATION-WITHOUT-STORAGE-PART - 2
  • LV148-SLOW DECREASE & ABRUPT INCREASE OF THE SUPPLY VOLTAGE
  • LV148-E48-08_RESET_BEHAVIOUR
  • LV148-E48-09:_SHORT_INTERRUPTIONS
  • LV148-E48-10:_START_IMPULSES
  • LV148-HW-E48-15_OPERATION_IN_RANGE_W/O_FUNC_RESTRICTION
  • LV148-E48-16:OPERATION_UPPER_RANGE_FUNC_LIMITATION
  • LV148-E48-17:OPERATION_LOWER_RANGE_FUNCTION_LIMITATION
  • LV148-E48-18:OVERVOLTAGE_RANGE
  • LV148-E48-19:UNDERVOLTAGE_RANGE
  • LV148-E48-20a:FAULT_CURRENT

9. EV

As per ECE-R10 V6 V7:

  • Annex 15 (EFT)
  • Annex 16 (Surge)
  • Annex 21 (BCI)
  • Annex 10 (ESD)

Get in Touch

Reach out to us for slot booking, calibration enquiries, or training programs.

📍 Lab Location: Complus Labs
68/60, 2nd Main Rd,
Rajajinagar Industrial Town,
Bangalore - 560 010
Karnataka, INDIA

📞 Phone: +91-80-41683883

✉️ Email: labs@complus.in

🕒 Working Hours: Monday – Saturday: 9:00 AM – 6:00 PM

Request a Quote / Book a Slot